Download
s12028-020-01146-4.pdf 3,01MB
WeightNameValue
1000 Titel
  • Automated Pupillometry Identifies Absence of Intracranial Pressure Elevation in Intracerebral Hemorrhage Patients
1000 Autor/in
  1. Giede-Jeppe, Antje |
  2. Sprügel, Maximilian I. |
  3. Huttner, Hagen B. |
  4. Borutta, Matthias |
  5. Kuramatsu, Joji B. |
  6. Hoelter, Philip |
  7. Engelhorn, Tobias |
  8. Schwab, Stefan |
  9. Koehn, Julia |
1000 Erscheinungsjahr 2020
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2020-12-24
1000 Erschienen in
1000 Quellenangabe
  • 35(1):210-220
1000 Copyrightjahr
  • 2020
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1007/s12028-020-01146-4 |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8285349/ |
1000 Publikationsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Introduction!#!Although automated pupillometry is increasingly used in critical care settings, predictive value of automatically assessed pupillary parameters during different intracranial pressure (ICP) levels and possible clinical implications are unestablished.!##!Methods!#!This retrospective cohort study at the neurocritical care unit of the University of Erlangen-Nuremberg (2016-2018) included 23 nontraumatic supratentorial (intracerebral hemorrhage) ICH patients without signs of abnormal pupillary function by manual assessment, i.e., absent light reflex. We assessed ICP levels by an external ventricular drain simultaneously with parameters of pupillary reactivity [i.e., maximum and minimum apertures, light reflex latency (Lat), constriction and redilation velocities (CV, DV), and percentage change of apertures (per-change)] using a portable pupillometer (NeurOptics®). Computed tomography (CT) scans were analyzed to determine lesion location, size, intraventricular hemorrhage, hydrocephalus, midline shift, and compression or absence of the basal cisterns. We performed receiver operating characteristics analysis to investigate associations of ICP levels with pupillary parameters and to determine best cutoff values for prediction of ICP elevation. After dichotomization of assessments according to ICP values (normal: < 20 mmHg, elevated: ≥ 20 mmHg), prognostic performance of the determined cutoff parameters of pupillary function versus of CT-imaging findings was analyzed by calculating sensitivity, specificity, positive and negative predictive values (logistic regression, corresponding ORs with 95% CIs).!##!Results!#!In 23 patients (11 women, median age 59.0 (51.0-69.0) years), 1,934 assessments were available for analysis. A total of 74 ICP elevations ≥ 20 mmHg occurred in seven patients. Best discriminative thresholds for ICP elevation were: CV < 0.8 mm/s (AUC 0.740), per-change < 10% (AUC 0.743), DV < 0.2 mm/s (AUC 0.703), and Lat > 0.3 s (AUC 0.616). Positive predictive value of all four parameters to indicate ICP elevation ranged between 7.2 and 8.3% only and was similarly low for CT abnormalities (9.1%). We found high negative predictive values of pupillary parameters [CV: 99.2% (95% CI 98.3-99.6), per-change: 98.7% (95% CI 97.8-99.2), DV: 98.0% (95% CI 97.0-98.7), Lat: 97.0% (95% CI 96.0-97.7)], and CT abnormalities [99.7% (95% CI 99.2-99.9)], providing evidence that both techniques adequately identified ICH patients without ICP elevation.!##!Conclusions!#!Our data suggest an association between noninvasively detected changes in pupillary reactivity and ICP levels in sedated ICH patients. Although automated pupillometry and neuroimaging seem not sufficient to noninvasively indicate ICP elevation, both techniques, however, adequately identified ICH patients without ICP elevation. This finding may facilitate routine management by saving invasive ICP monitoring or repeated CT controls in patients with specific automated pupillometry readings.
1000 Sacherschließung
lokal Constriction velocity
lokal Critical care
lokal Female [MeSH]
lokal Humans [MeSH]
lokal Intracranial pressure
lokal Pupillary reactivity
lokal Retrospective Studies [MeSH]
lokal Middle Aged [MeSH]
lokal Reflex, Pupillary [MeSH]
lokal Original Work
lokal Cerebral Hemorrhage/diagnostic imaging [MeSH]
lokal Intracerebral hemorrhage
lokal Intracranial Pressure [MeSH]
lokal Intracranial Hypertension/diagnosis [MeSH]
1000 Liste der Beteiligten
  1. https://frl.publisso.de/adhoc/uri/R2llZGUtSmVwcGUsIEFudGpl|https://frl.publisso.de/adhoc/uri/U3Byw7xnZWwsIE1heGltaWxpYW4gSS4=|https://frl.publisso.de/adhoc/uri/SHV0dG5lciwgSGFnZW4gQi4=|https://frl.publisso.de/adhoc/uri/Qm9ydXR0YSwgTWF0dGhpYXM=|https://frl.publisso.de/adhoc/uri/S3VyYW1hdHN1LCBKb2ppIEIu|https://frl.publisso.de/adhoc/uri/SG9lbHRlciwgUGhpbGlw|https://frl.publisso.de/adhoc/uri/RW5nZWxob3JuLCBUb2JpYXM=|https://frl.publisso.de/adhoc/uri/U2Nod2FiLCBTdGVmYW4=|https://frl.publisso.de/adhoc/uri/S29laG4sIEp1bGlh
1000 Hinweis
  • DeepGreen-ID: 438c5229f0414bdd9c917e9343f18d02 ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6471696.rdf
1000 Erstellt am 2023-11-18T15:06:13.665+0100
1000 Erstellt von 322
1000 beschreibt frl:6471696
1000 Zuletzt bearbeitet 2024-04-05T11:53:00.608+0200
1000 Objekt bearb. Fri Apr 05 11:53:00 CEST 2024
1000 Vgl. frl:6471696
1000 Oai Id
  1. oai:frl.publisso.de:frl:6471696 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source