Download
41747_2024_Article_502.pdf 1,43MB
WeightNameValue
1000 Titel
  • Low-dose high-resolution chest CT in adults with cystic fibrosis: intraindividual comparison between photon-counting and energy-integrating detector CT
1000 Autor/in
  1. Frings, Marko |
  2. Welsner, Matthias |
  3. Mousa, Christin |
  4. Zensen, Sebastian |
  5. Salhöfer, Luca |
  6. Meetschen, Mathias |
  7. Beck, Nikolas |
  8. Bos, Denise |
  9. Westhölter, Dirk |
  10. Wienker, Johannes |
  11. Taube, Christian |
  12. Umutlu, Lale |
  13. Schaarschmidt, Benedikt M. |
  14. Forsting, Michael |
  15. Haubold, Johannes |
  16. Sutharsan, Sivagurunathan |
  17. Opitz, Marcel |
1000 Verlag Springer Vienna
1000 Erscheinungsjahr 2024
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2024-09-19
1000 Erschienen in
1000 Quellenangabe
  • 8(1):105
1000 Copyrightjahr
  • 2024
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1186/s41747-024-00502-9 |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11413257/ |
1000 Publikationsstatus
1000 Begutachtungsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • <jats:title>Abstract</jats:title><jats:sec> <jats:title>Background</jats:title> <jats:p>Regular disease monitoring with low-dose high-resolution (LD-HR) computed tomography (CT) scans is necessary for the clinical management of people with cystic fibrosis (pwCF). The aim of this study was to compare the image quality and radiation dose of LD-HR protocols between photon-counting CT (PCCT) and energy-integrating detector system CT (EID-CT) in pwCF.</jats:p> </jats:sec><jats:sec> <jats:title>Methods</jats:title> <jats:p>This retrospective study included 23 pwCF undergoing LD-HR chest CT with PCCT who had previously undergone LD-HR chest CT with EID-CT. An intraindividual comparison of radiation dose and image quality was conducted. The study measured the dose-length product, volumetric CT dose index, effective dose and signal-to-noise ratio (SNR). Three blinded radiologists assessed the overall image quality, image sharpness, and image noise using a 5-point Likert scale ranging from 1 (deficient) to 5 (very good) for image quality and image sharpness and from 1 (very high) to 5 (very low) for image noise.</jats:p> </jats:sec><jats:sec> <jats:title>Results</jats:title> <jats:p>PCCT used approximately 42% less radiation dose than EID-CT (median effective dose 0.54 <jats:italic>versus</jats:italic> 0.93 mSv, <jats:italic>p</jats:italic> &lt; 0.001). PCCT was consistently rated higher than EID-CT for overall image quality and image sharpness. Additionally, image noise was lower with PCCT compared to EID-CT. The average SNR of the lung parenchyma was lower with PCCT compared to EID-CT (<jats:italic>p</jats:italic> &lt; 0.001).</jats:p> </jats:sec><jats:sec> <jats:title>Conclusion</jats:title> <jats:p>In pwCF, LD-HR chest CT protocols using PCCT scans provided significantly better image quality and reduced radiation exposure compared to EID-CT.</jats:p> </jats:sec><jats:sec> <jats:title>Relevance statement</jats:title> <jats:p>In pwCF, regular follow-up could be performed through photon-counting CT instead of EID-CT, with substantial advantages in terms of both lower radiation exposure and increased image quality.</jats:p> </jats:sec><jats:sec> <jats:title>Key Points</jats:title> <jats:p><jats:list list-type='bullet'> <jats:list-item> <jats:p>Photon-counting CT (PCCT) and energy-integrating detector system CT (EID-CT) were compared in 23 people with cystic fibrosis (pwCF).</jats:p> </jats:list-item> <jats:list-item> <jats:p>Image quality was rated higher for PCCT than for EID-CT.</jats:p> </jats:list-item> <jats:list-item> <jats:p>PCCT used approximately 42% less radiation dose and offered superior image quality than EID-CT.</jats:p> </jats:list-item> </jats:list></jats:p> </jats:sec><jats:sec> <jats:title>Graphical Abstract</jats:title> </jats:sec>
1000 Sacherschließung
lokal Female [MeSH]
lokal Adult [MeSH]
lokal Signal-To-Noise Ratio [MeSH]
lokal Humans [MeSH]
lokal Technology (radiologic)
lokal Radiation dosage
lokal Retrospective Studies [MeSH]
lokal Tomography (x-ray computed)
lokal Tomography, X-Ray Computed/methods [MeSH]
lokal Cystic fibrosis
lokal Original Article
lokal Photons [MeSH]
lokal Male [MeSH]
lokal Radiography, Thoracic/methods [MeSH]
lokal Young Adult [MeSH]
lokal Cystic Fibrosis/diagnostic imaging [MeSH]
lokal Radiation Dosage [MeSH]
lokal Radiation exposure
1000 Fächerklassifikation (DDC)
1000 Liste der Beteiligten
  1. https://frl.publisso.de/adhoc/uri/RnJpbmdzLCBNYXJrbw==|https://frl.publisso.de/adhoc/uri/V2Vsc25lciwgTWF0dGhpYXM=|https://frl.publisso.de/adhoc/uri/TW91c2EsIENocmlzdGlu|https://frl.publisso.de/adhoc/uri/WmVuc2VuLCBTZWJhc3RpYW4=|https://frl.publisso.de/adhoc/uri/U2FsaMO2ZmVyLCBMdWNh|https://frl.publisso.de/adhoc/uri/TWVldHNjaGVuLCBNYXRoaWFz|https://frl.publisso.de/adhoc/uri/QmVjaywgTmlrb2xhcw==|https://frl.publisso.de/adhoc/uri/Qm9zLCBEZW5pc2U=|https://frl.publisso.de/adhoc/uri/V2VzdGjDtmx0ZXIsIERpcms=|https://frl.publisso.de/adhoc/uri/V2llbmtlciwgSm9oYW5uZXM=|https://frl.publisso.de/adhoc/uri/VGF1YmUsIENocmlzdGlhbg==|https://frl.publisso.de/adhoc/uri/VW11dGx1LCBMYWxl|https://frl.publisso.de/adhoc/uri/U2NoYWFyc2NobWlkdCwgQmVuZWRpa3QgTS4=|https://frl.publisso.de/adhoc/uri/Rm9yc3RpbmcsIE1pY2hhZWw=|https://frl.publisso.de/adhoc/uri/SGF1Ym9sZCwgSm9oYW5uZXM=|https://frl.publisso.de/adhoc/uri/U3V0aGFyc2FuLCBTaXZhZ3VydW5hdGhhbg==|https://frl.publisso.de/adhoc/uri/T3BpdHosIE1hcmNlbA==
1000 Hinweis
  • DeepGreen-ID: 3092a62e63e84c018e3fb98c8fad6536 ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search) ; at least one of the mandatory fields 'given-names' and 'family-name' is missing for the ORCID profile of 'Frings, Marko' (https://orcid.org/0009-0001-5250-5751)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6490670.rdf
1000 Erstellt am 2025-02-03T12:02:56.959+0100
1000 Erstellt von 322
1000 beschreibt frl:6490670
1000 Zuletzt bearbeitet 2025-08-05T07:20:03.087+0200
1000 Objekt bearb. Tue Aug 05 07:20:03 CEST 2025
1000 Vgl. frl:6490670
1000 Oai Id
  1. oai:frl.publisso.de:frl:6490670 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source