Download
12903_2024_Article_5193.pdf 1,67MB
WeightNameValue
1000 Titel
  • Automated pipeline for linear and volumetric assessment of facial swelling after third molar surgery
1000 Autor/in
  1. Barone, Selene |
  2. Zaffino, Paolo |
  3. SALVIATI, MARIANNA |
  4. Destito, Michela |
  5. Antonelli, Alessandro |
  6. Bennardo, Francesco |
  7. Cevidanes, Lucia |
  8. SPADEA, Maria Francesca |
  9. Giudice, Amerigo |
1000 Verlag
  • BioMed Central
1000 Erscheinungsjahr 2024
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2024-11-19
1000 Erschienen in
1000 Quellenangabe
  • 24(1):1404
1000 Copyrightjahr
  • 2024
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1186/s12903-024-05193-7 |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11575084/ |
1000 Publikationsstatus
1000 Begutachtungsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • <jats:title>Abstract</jats:title><jats:sec> <jats:title>Background</jats:title> <jats:p>Extraction of mandibular third molars (M3Ms) is a routine procedure in oral and maxillofacial surgery, often associated with postoperative symptoms like pain, facial swelling, and trismus. This study aimed to introduce a standardized and automated protocol for swelling analysis following M3M surgery, presenting results regarding clinical conditions immediately and one-week after surgery.</jats:p> </jats:sec><jats:sec> <jats:title>Methods</jats:title> <jats:p>In a prospective study, 35 patients were enrolled (mean age: 24.4 ± 5.8 years) for removal of 54 M3Ms. Facial swelling was evaluated through 3D facial scans before surgery (T0), at three days (T1), and seven days (T2) post-surgery. The open-source software 3DSlicer facilitated automated analysis, including data anonymization, orientation, surface registration, qualitative comparisons, linear measurements, and volumetric quantification. Pairwise superimposition of facial models enabled qualitative, vectorial, and quantitative assessments, comparing initial conditions with swelling development at T1 and T2. Additionally, changes between T1 and T2 were also evaluated. Secondary outcomes encompassed clinical evaluations of pain, trismus (maximum mouth opening), and surgery time. Statistical analysis involved the paired Student t-test to assess longitudinal changes and analysis of variance to evaluate outcome variables concerning difficulty scores. Linear regression models correlated primary outcome variables with secondary study variables (α &lt; 0.05).</jats:p> </jats:sec><jats:sec> <jats:title>Results</jats:title> <jats:p>Longitudinal analysis demonstrated significant but variable facial swelling, pain, and trismus at T1, followed by improvement at T2 (<jats:italic>p</jats:italic> &lt; 0.001). Linear and volumetric differences correlated positively with surgery time (<jats:italic>p</jats:italic> &lt; 0.05). A direct proportionality between linear and volume differences was observed, higher values at T1 correlated with higher values at T2 (<jats:italic>p</jats:italic> &lt; 0.05).</jats:p> </jats:sec><jats:sec> <jats:title>Conclusions</jats:title> <jats:p>An innovative digital workflow for precise quantification of postoperative facial changes was implemented, incorporating volumetric measurements that surpass linear assessments. Clinical conditions demonstrated a direct correlation with surgery time, deteriorating immediately and improving one-week after surgery.</jats:p> </jats:sec>
1000 Sacherschließung
lokal Tooth Extraction/adverse effects [MeSH]
lokal Volumetric measurements
lokal Trismus/etiology [MeSH]
lokal Molar, Third/diagnostic imaging [MeSH]
lokal Tooth Extraction/methods [MeSH]
lokal Male [MeSH]
lokal Third molar surgery edema
lokal Edema/etiology [MeSH]
lokal Imaging, Three-Dimensional/methods [MeSH]
lokal Pain, Postoperative/etiology [MeSH]
lokal 3D swelling analysis
lokal Female [MeSH]
lokal Mandible/diagnostic imaging [MeSH]
lokal Postoperative Complications [MeSH]
lokal Adult [MeSH]
lokal Humans [MeSH]
lokal Prospective Studies [MeSH]
lokal Face/diagnostic imaging [MeSH]
lokal Edema/diagnostic imaging [MeSH]
lokal Facial scanner
lokal Research
lokal Young Adult [MeSH]
lokal Mandible/surgery [MeSH]
lokal Molar, Third/surgery [MeSH]
lokal Three-dimensional surface imaging
1000 Fächerklassifikation (DDC)
1000 Liste der Beteiligten
  1. https://orcid.org/0000-0002-0701-2675|https://orcid.org/0000-0002-0219-0157|https://orcid.org/0000-0002-8913-6371|https://orcid.org/0000-0002-1720-3029|https://orcid.org/0000-0002-9557-3586|https://orcid.org/0000-0002-6528-2681|https://orcid.org/0000-0001-9786-2253|https://orcid.org/0000-0002-5339-9583|https://orcid.org/0000-0002-5091-6979
1000 Hinweis
  • DeepGreen-ID: 1d28a5e324e347fda555a3bf2721136e ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6506644.rdf
1000 Erstellt am 2025-02-06T11:52:44.289+0100
1000 Erstellt von 322
1000 beschreibt frl:6506644
1000 Zuletzt bearbeitet 2025-07-30T08:42:55.338+0200
1000 Objekt bearb. Wed Jul 30 08:42:55 CEST 2025
1000 Vgl. frl:6506644
1000 Oai Id
  1. oai:frl.publisso.de:frl:6506644 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source