  • Quantification of breast biopsy clip marker artifact on routine breast MRI sequences: a phantom study
1000 Autor/in
  1. Kremser, Christian |
  2. Gruber, Leonhard |
  3. Dietzel, Matthias |
  4. Amort, Birgit |
  5. Santner, Wolfram |
  6. Daniaux, Martin |
1000 Verlag Springer Vienna
1000 Erscheinungsjahr 2024
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2024-11-15
1000 Erschienen in
1000 Quellenangabe
  • 8(1):128
1000 Copyrightjahr
  • 2024
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1186/s41747-024-00525-2 |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11568078/ |
1000 Publikationsstatus
1000 Begutachtungsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • <jats:title>Abstract</jats:title><jats:sec> <jats:title>Background</jats:title> <jats:p>To investigate the artifact sizes of four common breast clip-markers on a standard breast magnetic resonance imaging (MRI) protocol in an <jats:italic>in vitro</jats:italic> phantom model.</jats:p> </jats:sec><jats:sec> <jats:title>Methods</jats:title> <jats:p>Using 1.5-T and 3-T whole-body scanners with an 18-channel breast coil, artifact dimensions of four breast biopsy markers in an agarose-gel phantom were measured by two readers on images obtained with the following sequences: T2-weighted fast spin-echo short inversion time fat-suppressed inversion-recovery with magnitude reconstruction (T2-TIRM); T1-weighted spoiled gradient-echo with fat suppression (T1_FL3D), routinely used for dynamic contrast-enhanced imaging; diffusion-weighted imaging (DWI), including a readout segmented echo-planar imaging (RESOLVE-DWI) and echo-planar imaging sequence (EPI-DWI). After outlining the artifacts by freehand regions of interest, sagittal and lateral diameters in axial images were measured.</jats:p> </jats:sec><jats:sec> <jats:title>Results</jats:title> <jats:p>Interreader agreement for artifact size quantification was high, depending on the sequence (80.4–94.8%). Overall, the size, shape, and appearance of artifacts depended on clip type and MRI sequence. The artifact size ranged from 5.7 × 8.5 mm<jats:sup>2</jats:sup> to 13.4 × 17.7 mm<jats:sup>2</jats:sup> at 1.5 T and from 6.6 × 8.2 mm<jats:sup>2</jats:sup> to 17.7 × 20.7 mm<jats:sup>2</jats:sup> at 3 T. Clip artifacts were largest on EPI-DWI and RESOLVE-DWI (<jats:italic>p</jats:italic> ≤ 0.016). In three out of four clips, T2-TIRM showed the smallest artifact (<jats:italic>p</jats:italic> ≤ 0.002), while in one clip the artifact was smallest on T1_FL3D (<jats:italic>p</jats:italic> = 0.026). With the exception of one clip in the RESOLVE sequence, all clips showed a decrease in the artifact area from DWI to ADC images (<jats:italic>p</jats:italic> ≤ 0.037).</jats:p> </jats:sec><jats:sec> <jats:title>Conclusion</jats:title> <jats:p>Breast clip-marker MRI artifact appearances depend on clip type, field strength, and sequence and may reach a significant size, potentially obscuring smaller lesions and hindering accurate assessment of breast tumors.</jats:p> </jats:sec><jats:sec> <jats:title>Relevance statement</jats:title> <jats:p>Considerable variations in artifact size and characteristics across different breast clips, MRI sequences, and field strengths exist. Awareness of these artifacts and their characteristics is essential to ensure accurate interpretation of scans and appropriate treatment planning.</jats:p> </jats:sec><jats:sec> <jats:title>Key Points</jats:title> <jats:p><jats:list list-type='bullet'> <jats:list-item> <jats:p>Awareness of breast clip artifacts is essential for accurate interpretation of MRI.</jats:p> </jats:list-item> <jats:list-item> <jats:p>The appearance of artifacts depends on breast clip type, field strength, and sequence.</jats:p> </jats:list-item> <jats:list-item> <jats:p>Clip-related artifacts might hinder the visibility of small lesions.</jats:p> </jats:list-item> </jats:list></jats:p> </jats:sec><jats:sec> <jats:title>Graphical Abstract</jats:title> </jats:sec>
1000 Sacherschließung
lokal Clips
lokal Female [MeSH]
lokal Biopsy [MeSH]
lokal Humans [MeSH]
lokal Artifacts [MeSH]
lokal Original Article
lokal Artifacts
lokal Breast/diagnostic imaging [MeSH]
lokal Phantoms, Imaging [MeSH]
lokal Breast neoplasms
lokal Magnetic resonance imaging
lokal Magnetic Resonance Imaging/methods [MeSH]
lokal Biopsy
1000 Fächerklassifikation (DDC)
1000 Liste der Beteiligten
  1. https://frl.publisso.de/adhoc/uri/S3JlbXNlciwgQ2hyaXN0aWFu|https://orcid.org/0000-0003-3351-799X|https://frl.publisso.de/adhoc/uri/RGlldHplbCwgTWF0dGhpYXM=|https://frl.publisso.de/adhoc/uri/QW1vcnQsIEJpcmdpdA==|https://frl.publisso.de/adhoc/uri/U2FudG5lciwgV29sZnJhbQ==|https://frl.publisso.de/adhoc/uri/RGFuaWF1eCwgTWFydGlu
1000 Hinweis
  • DeepGreen-ID: cde50092997b44afb1cfadfe852b748e ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6517581.rdf
1000 Erstellt am 2025-07-05T05:21:25.556+0200
1000 Erstellt von 322
1000 beschreibt frl:6517581
1000 Zuletzt bearbeitet 2025-08-19T19:40:21.845+0200
1000 Objekt bearb. Tue Aug 19 19:40:21 CEST 2025
1000 Vgl. frl:6517581
1000 Oai Id
  1. oai:frl.publisso.de:frl:6517581 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source