Download
41747_2024_Article_454.pdf 2,82MB
WeightNameValue
1000 Titel
  • Chondrosarcoma evaluation using hematein-based x-ray staining and high-resolution 3D micro-CT: a feasibility study
1000 Autor/in
  1. Gersing, Alexandra |
  2. Kimm, Melanie A. |
  3. Bollwein, Christine |
  4. Ilg, Patrick |
  5. Mogler, Carolin |
  6. Gassert, Felix G. |
  7. Feuerriegel, Georg C. |
  8. Knebel, Carolin |
  9. Woertler, Klaus |
  10. Pfeiffer, Daniela |
  11. Busse, Madleen |
  12. Pfeiffer, Franz |
1000 Verlag Springer Vienna
1000 Erscheinungsjahr 2024
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2024-05-13
1000 Erschienen in
1000 Quellenangabe
  • 8(1):58
1000 Copyrightjahr
  • 2024
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1186/s41747-024-00454-0 |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11089022/ |
1000 Publikationsstatus
1000 Begutachtungsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • <jats:title>Abstract</jats:title><jats:sec> <jats:title>Background</jats:title> <jats:p>Chondrosarcomas are rare malignant bone tumors diagnosed by analyzing radiological images and histology of tissue biopsies and evaluating features such as matrix calcification, cortical destruction, trabecular penetration, and tumor cell entrapment.</jats:p> </jats:sec><jats:sec> <jats:title>Methods</jats:title> <jats:p>We retrospectively analyzed 16 cartilaginous tumor tissue samples from three patients (51-, 54-, and 70-year-old) diagnosed with a dedifferentiated chondrosarcoma at the femur, a moderately differentiated chondrosarcoma in the pelvis, and a predominantly moderately differentiated chondrosarcoma at the scapula, respectively. We combined a hematein-based x-ray staining with high-resolution three-dimensional (3D) microscopic x-ray computed tomography (micro-CT) for nondestructive 3D tumor assessment and tumor margin evaluation.</jats:p> </jats:sec><jats:sec> <jats:title>Results</jats:title> <jats:p>We detected trabecular entrapment on 3D micro-CT images and followed bone destruction throughout the volume. In addition to staining cell nuclei, hematein-based staining also improved the visualization of the tumor matrix, allowing for the distinction between the tumor and the bone marrow cavity. The hematein-based staining did not interfere with further conventional histology. There was a 5.97 ± 7.17% difference between the relative tumor area measured using micro-CT and histopathology (<jats:italic>p</jats:italic> = 0.806) (Pearson correlation coefficient <jats:italic>r</jats:italic> = 0.92, <jats:italic>p</jats:italic> = 0.009). Signal intensity in the tumor matrix (4.85 ± 2.94) was significantly higher in the stained samples compared to the unstained counterparts (1.92 ± 0.11, <jats:italic>p</jats:italic> = 0.002).</jats:p> </jats:sec><jats:sec> <jats:title>Conclusions</jats:title> <jats:p>Using nondestructive 3D micro-CT, the simultaneous visualization of radiological and histopathological features is feasible.</jats:p> </jats:sec><jats:sec> <jats:title>Relevance statement</jats:title> <jats:p>3D micro-CT data supports modern radiological and histopathological investigations of human bone tumor specimens. It has the potential for being an integrative part of clinical preoperative diagnostics.</jats:p> </jats:sec><jats:sec> <jats:title>Key points</jats:title> <jats:p>• Matrix calcifications are a relevant diagnostic feature of bone tumors.</jats:p> <jats:p>• Micro-CT detects all clinically diagnostic relevant features of x-ray-stained chondrosarcoma.</jats:p> <jats:p>• Micro-CT has the potential to be an integrative part of clinical diagnostics.</jats:p> </jats:sec><jats:sec> <jats:title>Graphical Abstract</jats:title> </jats:sec>
1000 Sacherschließung
lokal Female [MeSH]
lokal Hematein
lokal Aged [MeSH]
lokal Humans [MeSH]
lokal Staining and Labeling/methods [MeSH]
lokal Retrospective Studies [MeSH]
lokal Middle Aged [MeSH]
lokal Feasibility Studies [MeSH]
lokal X-ray microtomography
lokal Original Article
lokal Chondrosarcoma/pathology [MeSH]
lokal Male [MeSH]
lokal Chondrosarcoma
lokal X-Ray Microtomography/methods [MeSH]
lokal Chondrosarcoma/diagnostic imaging [MeSH]
lokal Imaging, Three-Dimensional/methods [MeSH]
lokal Staining and labeling
lokal Bone Neoplasms/diagnostic imaging [MeSH]
lokal Bone Neoplasms/pathology [MeSH]
lokal Bone neoplasms
1000 Fächerklassifikation (DDC)
1000 Liste der Beteiligten
  1. https://orcid.org/0000-0003-1687-5541|https://orcid.org/0000-0001-6833-9738|https://frl.publisso.de/adhoc/uri/Qm9sbHdlaW4sIENocmlzdGluZQ==|https://frl.publisso.de/adhoc/uri/SWxnLCBQYXRyaWNr|https://frl.publisso.de/adhoc/uri/TW9nbGVyLCBDYXJvbGlu|https://frl.publisso.de/adhoc/uri/R2Fzc2VydCwgRmVsaXggRy4=|https://frl.publisso.de/adhoc/uri/RmV1ZXJyaWVnZWwsIEdlb3JnIEMu|https://frl.publisso.de/adhoc/uri/S25lYmVsLCBDYXJvbGlu|https://frl.publisso.de/adhoc/uri/V29lcnRsZXIsIEtsYXVz|https://frl.publisso.de/adhoc/uri/UGZlaWZmZXIsIERhbmllbGE=|https://frl.publisso.de/adhoc/uri/QnVzc2UsIE1hZGxlZW4=|https://frl.publisso.de/adhoc/uri/UGZlaWZmZXIsIEZyYW56
1000 Hinweis
  • DeepGreen-ID: a8a3a862235b4d8791ae4b243fd19621 ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search) ;
1000 Label
1000 Förderer
  1. Universitätsklinik München |
1000 Fördernummer
  1. -
1000 Förderprogramm
  1. -
1000 Dateien
1000 Förderung
  1. 1000 joinedFunding-child
    1000 Förderer Universitätsklinik München |
    1000 Förderprogramm -
    1000 Fördernummer -
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6521255.rdf
1000 Erstellt am 2025-07-06T06:41:49.818+0200
1000 Erstellt von 322
1000 beschreibt frl:6521255
1000 Zuletzt bearbeitet 2025-08-04T08:28:51.491+0200
1000 Objekt bearb. Mon Aug 04 08:28:51 CEST 2025
1000 Vgl. frl:6521255
1000 Oai Id
  1. oai:frl.publisso.de:frl:6521255 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source