  • WALANT–Epinephrine injection may lead to short term, reversible episodes of critical oxygen saturation in the fingertips
1000 Autor/in
  1. Moog, P. |
  2. Dozan, M. |
  3. Betzl, J. |
  4. Sukhova, I. |
  5. Kükrek, H. |
  6. Megerle, K. |
1000 Erscheinungsjahr 2021
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2021-01-23
1000 Erschienen in
1000 Quellenangabe
  • 141(3):527-533
1000 Copyrightjahr
  • 2021
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1007/s00402-020-03744-5 |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7900334/ |
1000 Publikationsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Introduction!#!Although the WALANT technique's long-term safeness has been demonstrated in many studies, there are only few data investigating its short-term effects on tissue perfusion and oxygen levels. It was hypothesized that, temporarily, critical levels of tissue perfusion may occur.!##!Methods!#!Seventeen patients, who were scheduled for different procedures in WALANT technique, were injected with 5-7 ml of 1% Articain containing 1:200,000 epinephrine at the finger base. Capillary-venous oxygen saturation, hemoglobin volume in the capillaries, and relative blood flow in the fingertips were recorded once per second by white light spectrometry and laser Doppler flowmetry before, during and after injection for an average of 32 min.!##!Results!#!Clinically, no persistent tissue malperfusion was observed, and there were no postoperative complications. Capillary-venous oxygen saturation was reduced by ≥ 30% in seven patients. Critical levels of oxygen saturation were detected in four patients during 13 intervals, each lasting for 132.5 s on average. Oxygen saturation returned to noncritical values in all patients by the end of the observation period. Blood flow in the fingertips was reduced by more than 30% in nine patients, but no critical levels were observed, as with the hemoglobin. Three patients demonstrated a reactive increase in blood flow of more than 30% after injection.!##!Conclusions!#!Injection of tumescent local anesthesia containing epinephrine into finger base may temporarily cause a substantial reduction in blood flow and lead to critical levels of oxygen saturation in the fingertips. However, this was fully reversible within minutes and does not cause long-term complications.
1000 Sacherschließung
lokal Oxygen/blood [MeSH]
lokal Wide awake surgery
lokal Epinephrine/therapeutic use [MeSH]
lokal Humans [MeSH]
lokal Anesthetics, Local/therapeutic use [MeSH]
lokal Fingers/surgery [MeSH]
lokal Epinephrine/administration
lokal Epinephrine
lokal Digital nerve block anesthesia
lokal WALANT
lokal Fingers/blood supply [MeSH]
lokal Handsurgery
lokal Anesthetics, Local/administration
lokal Anesthesia, Local/methods [MeSH]
lokal Finger necrosis
1000 Liste der Beteiligten
  1. https://frl.publisso.de/adhoc/uri/TW9vZywgUC4=|https://frl.publisso.de/adhoc/uri/RG96YW4sIE0u|https://frl.publisso.de/adhoc/uri/QmV0emwsIEou|https://frl.publisso.de/adhoc/uri/U3VraG92YSwgSS4=|https://frl.publisso.de/adhoc/uri/S8O8a3JlaywgSC4=|https://frl.publisso.de/adhoc/uri/TWVnZXJsZSwgSy4=
1000 Hinweis
  • DeepGreen-ID: c830c4b1e4f14ec5ad43b87c753d978e ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6447456.rdf
1000 Erstellt am 2023-04-28T16:06:33.137+0200
1000 Erstellt von 322
1000 beschreibt frl:6447456
1000 Zuletzt bearbeitet 2023-10-20T20:42:07.828+0200
1000 Objekt bearb. Fri Oct 20 20:42:07 CEST 2023
1000 Vgl. frl:6447456
1000 Oai Id
  1. oai:frl.publisso.de:frl:6447456 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source