Download
s00330-021-08284-z.pdf 1,17MB
WeightNameValue
1000 Titel
  • Automated detection of the contrast phase in MDCT by an artificial neural network improves the accuracy of opportunistic bone mineral density measurements
1000 Autor/in
  1. Rühling, Sebastian |
  2. Navarro, Fernando |
  3. Sekuboyina, Anjany |
  4. El Husseini, Malek |
  5. Baum, Thomas |
  6. Menze, Bjoern |
  7. Braren, Rickmer |
  8. Zimmer, Claus |
  9. Kirschke, Jan |
1000 Erscheinungsjahr 2021
1000 Publikationstyp
  1. Artikel |
1000 Online veröffentlicht
  • 2021-10-23
1000 Erschienen in
1000 Quellenangabe
  • 32(3):1465-1474
1000 Copyrightjahr
  • 2021
1000 Lizenz
1000 Verlagsversion
  • https://doi.org/10.1007/s00330-021-08284-z |
  • https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8831336/ |
1000 Publikationsstatus
1000 Begutachtungsstatus
1000 Sprache der Publikation
1000 Abstract/Summary
  • Objectives!#!To determine the accuracy of an artificial neural network (ANN) for fully automated detection of the presence and phase of iodinated contrast agent in routine abdominal multidetector computed tomography (MDCT) scans and evaluate the effect of contrast correction for osteoporosis screening.!##!Methods!#!This HIPPA-compliant study retrospectively included 579 MDCT scans in 193 patients (62.4 ± 14.6 years, 48 women). Three different ANN models (2D DenseNet with random slice selection, 2D DenseNet with anatomy-guided slice selection, 3D DenseNet) were trained in 462 MDCT scans of 154 patients (threefold cross-validation), who underwent triphasic CT. All ANN models were tested in 117 unseen triphasic scans of 39 patients, as well as in a public MDCT dataset containing 311 patients. In the triphasic test scans, trabecular volumetric bone mineral density (BMD) was calculated using a fully automated pipeline. Root-mean-square errors (RMSE) of BMD measurements with and without correction for contrast application were calculated in comparison to nonenhanced (NE) scans.!##!Results!#!The 2D DenseNet with anatomy-guided slice selection outperformed the competing models and achieved an F1 score of 0.98 and an accuracy of 98.3% in the test set (public dataset: F1 score 0.93; accuracy 94.2%). Application of contrast agent resulted in significant BMD biases (all p < .001; portal-venous (PV): RMSE 18.7 mg/ml, mean difference 17.5 mg/ml; arterial (AR): RMSE 6.92 mg/ml, mean difference 5.68 mg/ml). After the fully automated correction, this bias was no longer significant (p > .05; PV: RMSE 9.45 mg/ml, mean difference 1.28 mg/ml; AR: RMSE 3.98 mg/ml, mean difference 0.94 mg/ml).!##!Conclusion!#!Automatic detection of the contrast phase in multicenter CT data was achieved with high accuracy, minimizing the contrast-induced error in BMD measurements.!##!Key points!#!• A 2D DenseNet with anatomy-guided slice selection achieved an F1 score of 0.98 and an accuracy of 98.3% in the test set. In a public dataset, an F1 score of 0.93 and an accuracy of 94.2% were obtained. • Automated adjustment for contrast injection improved the accuracy of lumbar bone mineral density measurements (RMSE 18.7 mg/ml vs. 9.45 mg/ml respectively, in the portal-venous phase). • An artificial neural network can reliably reveal the presence and phase of iodinated contrast agent in multidetector CT scans ( https://github.com/ferchonavarro/anatomy_guided_contrast_c ). This allows minimizing the contrast-induced error in opportunistic bone mineral density measurements.
1000 Sacherschließung
lokal Bone Density [MeSH]
lokal Female [MeSH]
lokal Machine learning
lokal Humans [MeSH]
lokal Retrospective Studies [MeSH]
lokal Osteoporosis
lokal Neural Networks, Computer [MeSH]
lokal Multidetector computed tomography
lokal Osteoporosis/diagnostic imaging [MeSH]
lokal Multidetector Computed Tomography [MeSH]
lokal Musculoskeletal
lokal Bone density
lokal Screening
1000 Liste der Beteiligten
  1. https://frl.publisso.de/adhoc/uri/UsO8aGxpbmcsIFNlYmFzdGlhbg==|https://frl.publisso.de/adhoc/uri/TmF2YXJybywgRmVybmFuZG8=|https://frl.publisso.de/adhoc/uri/U2VrdWJveWluYSwgQW5qYW55|https://frl.publisso.de/adhoc/uri/RWwgSHVzc2VpbmksIE1hbGVr|https://frl.publisso.de/adhoc/uri/QmF1bSwgVGhvbWFz|https://frl.publisso.de/adhoc/uri/TWVuemUsIEJqb2Vybg==|https://frl.publisso.de/adhoc/uri/QnJhcmVuLCBSaWNrbWVy|https://frl.publisso.de/adhoc/uri/WmltbWVyLCBDbGF1cw==|https://orcid.org/0000-0002-7557-0003
1000 Hinweis
  • DeepGreen-ID: 99d629418a274138baeade656e4a7d81 ; metadata provieded by: DeepGreen (https://www.oa-deepgreen.de/api/v1/), LIVIVO search scope life sciences (http://z3950.zbmed.de:6210/livivo), Crossref Unified Resource API (https://api.crossref.org/swagger-ui/index.html), to.science.api (https://frl.publisso.de/), ZDB JSON-API (beta) (https://zeitschriftendatenbank.de/api/), lobid - Dateninfrastruktur für Bibliotheken (https://lobid.org/resources/search)
1000 Label
1000 Dateien
1000 Objektart article
1000 Beschrieben durch
1000 @id frl:6451179.rdf
1000 Erstellt am 2023-05-11T12:28:59.307+0200
1000 Erstellt von 322
1000 beschreibt frl:6451179
1000 Zuletzt bearbeitet Sat Oct 21 04:26:34 CEST 2023
1000 Objekt bearb. Sat Oct 21 04:26:34 CEST 2023
1000 Vgl. frl:6451179
1000 Oai Id
  1. oai:frl.publisso.de:frl:6451179 |
1000 Sichtbarkeit Metadaten public
1000 Sichtbarkeit Daten public
1000 Gegenstand von

View source